TC-3U46 3U 460W
AC Input:
VOLTAGE:90~132 or 185~260V, (115/230 auto)
FREQUENCY:50/60Hz
INPUT CURRENT:8A/4A For 115/230VAC
INRUSH CURRENT:60A/80A MAX FOR 115/230
DC Output:
OUTPUT
VOLTAGE
|
OUTPUT CURRENT
|
REGULATION
|
OUTPUT
|
MIN(A)
|
MAX(A)
|
LOAD
|
LINE
|
RIPPLE & NOISE
MAX.[P-P]
|
+5V
|
3
|
40
|
±5%
|
±1%
|
50mV
|
+12V
|
2
|
24
|
±5%
|
±1%
|
120mV
|
-5V
|
0.1
|
0.3
|
±10%
|
±1%
|
150mV
|
-12V
|
0.1
|
0.8
|
±10%
|
±1%
|
150mV
|
+3.3V
|
1
|
20
|
±5%
|
±1%
|
50mV
|
+5VSB
|
0.1
|
2
|
±5%
|
±1%
|
50mV
|
The combined output power +5V&+3.3V shall not exceed 200W.
The total power shall not exceed 460W.
Features…
l Temperature range:Operation 0℃~50 ℃
l Hold up time:16ms at maximum load&normal input voltage
l Efficiency:68% Typical(Normal Line)
l Power good signal:Should be asserted high to indicate that+5VDC and +3.3VDC output are above the low voltage thresholds. Compatible signal out with 100ms to 500ms.
l Over power protection:The power supply shall shout down output
power exceeds 130% to 160%
l Over voltage protection:Standard on +5.0V, set at 6.25VDC ± 0.75VDC
l Short circuit protection:A short circuit placed between the DC return
and the output shall cause no damage and the power supply shall
shutdown.
l EMI:FCC part 15, subpart B, Class B, EN55022 CISPR22 Class B.
l Agency approvals:UL60950, CAN/CSA22.2 No.60950, TUV(IEC60950)
l Mtbf of power supply electronnis:100,000 hours at 25℃.
Life expctancy of fan 40,000 hours at 40℃
l Cooling:By forced air 1x80mm Fan
l Dimension:D180 X W117 X H86mm